HyperPure ASTM F1960 Installation Registration

Name(*)
Please let us know your name.

Email(*)
Please let us know your email address.

Phone Number(*)
Format: ###-###-####

Company(*)
Enter your Company's Name.

Company's Address(*)
Enter your Company's Address.

Company's Address 2(*)
Invalid Input

Company's City(*)
Enter your Company's City.

Company's State(*)
Select your Company's state or province.

Company's ZipCode(*)
Enter your company's zip code.

Trainer's Name(*)
Enter the name of the person who trained you.

Questions:

1. The fitting must be inserted into the expanded end of the tubing and ring, fully up to the fitting stops.(*)

Choose an answer.

2. Tubing should only be expanded as many times as needed to fully insert the fitting into the tube. More is not better.(*)

Choose an answer.

3. You must cut the HyperPure tubing perpendicular to its length, prior to installing the PEXa expansion ring and making the expansions.(*)

Choose an answer.

4. You must ensure that the expander head is rotated in between each expansion prior to insertion of the fitting.(*)

Choose an answer.

5. Only Milwaukee tools with Milwaukee Auto-Rotating Heads that are battery powered are allowed to be used on HyperPure ASTM F1960 fitting assemblies.(*)

Choose an answer.

6. Depending upon the temperature in which the assembly is constructed, it may take 24 hours or more to properly seal.(*)

Choose an answer.

7. What is the recommended number of expansions according to Table 1 in the installation instructions for ½” tubing using the Milwaukee M12 tool?(*)

Choose an answer.

8. You should NOT assemble HyperPure tubing with ASTM F1960 in temperatures lower than 20° F.(*)

Choose an answer.

9. All ASTM F1960 fittings installed with HyperPure tubing should be pressure tested after assembly.(*)

Choose an answer.

10. Both brass and plastic (PPSU) ASTM F1960 fittings (must be NSF 14 certified) are approved with HyperPure tubing. (*)

Choose an answer.

11. You should hold the tool in the tubing as long as possible before inserting the fitting.(*)

Choose an answer.

12. Temperature does NOT affect the time required for 1960 fittings to properly seal with HyperPure tubing.(*)

Choose an answer.

13. There should not be more that 1/16 inch gap between the expansion ring and the fitting pipe stop.(*)

Choose an answer.

14. PEXa rings are required for proper installation of the 1960 fittings into Legend HyperPure tubing.(*)

Choose an answer.

15. Pressure testing after assembly is not required for ASTM F1960 connections.(*)

Choose an answer.

Are you a robot?(*)
Are you a robot?
  RefreshInvalid Input

Type in what you see.